Dissolved Oxygen (DO) Meters - UK (2024)

Meet your regulatory needs with technology that is ideal for a wide range of applications and advanced dissolved oxygen analysis in the lab. Orion advanced and premium benchtop meters offer the flexibility to measure both polargraphic and optical technology. A dedicated kit, complete with BOD stirrer probe needed to fit in a DO bottle for airtight incubation, is available with the Orion Star A213 meter.

Calibrate using water-saturated air, air-saturated water, or custom value, using Winkler titration or zero point options. Log up to 2,000 data point sets with time/date stamp, and easily transfer calibration and data logs via USB or RS232 to a printer or computer when using an Orion advanced or premium dissolved oxygen meter.

Browse the complete portfolio or speak with an expert for assistance.

Contact us

Watch video

Select your dissolved oxygen bench or portable meters

  • Orion Bench Meters
  • Orion Portable Meters
  • Eutech Bench Meters
  • Eutech Portable Meters

Premium

Advanced

Basic

Orion Versa Star Pro RDO/DO
(VSTAR30series)
Orion Star A213 RDO/DO
(STARA2130 series)
Orion Lab Star DO113 DO
(Lab Star series)

Versatile, high-performance laboratory measurement systemEasy-to-use, dependable laboratory metersEconomical, simplified
laboratory meters
Ideal for
applications in:
Pharmaceuticals, biotechnology, food and beverage, industrialWater,
wastewater,
chemical, contract testing
Academic,
environmental,
power
Compatible probesOptical, polarographicOptical, polarographicPolarographic
DO range (polarographic)0 to 90 mg/L, 0 to 600%0 to 90 mg/L, 0 to 600%0 to 30 mg/L, 0 to 300%
DO range (RDO optical)0 to 50 mg/L, 0 to 500%0 to 50 mg/L, 0 to 500%---
DO calibration modesWater-saturated air, air-saturated water, manual (Winkler), zero pointWater-saturated air, air-saturated water, manual (Winkler), zero point100% and 0% saturation; custom concentration value
Barometric pressure compensationAutomatic with built-in barometerAutomatic with built-in barometerAutomatic with manual value input
Salinity correctionAutomatic with conductivity module and probe or manual inputAutomatic with manual factor inputAutomatic with manual factor input
Backlit displayYesYesYes
Number of channels4, customizable with modules11
Stirrer probe inputs21---
Data log2,000 with date/time2,000 with date/time500 sets with date/time
Calibration log30 per mode101
Identification optionsElectrode ID, sample ID, user IDSample ID, user ID---
Data export outputComputer or printerComputer or printerComputer or printer
Power supplyUniversal, 1000150–240 VAC, 50–60 Hz (Cat. No. STARA-PWR)Universal, 100–240 VAC, 50–60 Hz (Cat. No. 1010003) or 4 AA batteriesUniversal, 100–240 VAC, 50–60 Hz (Cat. No. LSTAR-PWR), 9DC adapter, 1.3A
Enhance your productivity with accessories for your benchtop and portable meters.Meter Accessories ›

Premium

Advanced

Basic

Orion Star A323 Dissolved Oxygen
(STARA3230 series)
Orion Star A223 Dissolved Oxygen
(STARA2230 series)
Orion Star A123 Dissolved Oxygen
(STARA1230 series)
Compatible probesRDO, polarographicRDO, polarographicPolarographic
DO range (polarographic)0 to 600% saturation0 to 600% saturation0 to 200% Saturation
DO range (RDO optical)0 to 50 mg/L0 to 50 mg/L---
DO calibration modesWater-saturated air, air saturated water, manual (Winkler), and zero pointWater-saturated air, air saturated water, manual (Winkler), and zero pointWater-saturated air, manual (Winkler)
Barometric pressure compensation400 to 850 mmHg,
automatic or manual
400 to 850 mmHg,
automatic or manual
---
Salinity Correction0 to 45 ppt0 to 45 ppt0 to 45
Backlit DisplayYesYes---
Number of channels111
Data log5000 with time and date stamp1000 with time and date stamp50
Data export optionsRS232,USBRS232, USBRS232, USB
AC AdapterOptional—universal,
100-240 VAC
Optional—universal,
100-240 VAC
Optional—universal,
100-240 VAC
Battery powerIncluded—4AA'sIncluded—4AA'sIncluded—4AA's
Enhance your productivity with accessories for your benchtop and portable meters.Meter Accessories ›

Advanced

Basic

Eutech DO2700 Dissolved Oxygen Bench MeterEutech 1730 Dissolved Oxygen Bench Meter

Economical, routine laboratory metersBudget-friendly, simple laboratory meters
Compatible probesPolarographicGalvanic
DO range (Polarographic)0.00 to 50.00 mg/L; 0 to 600.0 % saturation---
DO range (Galvanic)---0 to 30 mg/L; 0 to 300.0 % saturation
DO calibration modesWater-saturated air, zero point, manual (Winkler)100% and 0% saturation, manual concentration value (Winkler)
Barometric pressure compensationAutomatic with built-in barometerAutomatic with manual value entry
Salinity correctionAutomatic with manual value entryAutomatic with manual value entry
Range (temperature)0.0 to 50.0 °C, 32.0 to 122.0 °F-5.0 to 105.0 ºC
Backlit displayYesYes
Number of channels11
Stirrer probe inputsYes---
Data log500 with date/time500 with date/time
Calibration logMost recent viewable on meter and stored in meter memoryActive dissolved oxygen, temperature with time and date
Data export optionsRS232Computer or printe
Power supplyUniversal, 100-240VAC, 50/60 Hz, Cat. No. 60X426401Universal, 100–240VAC, 50–60Hz (Cat. No. EB1700PWR), 9 DC adapter, 1.3A

").addClass("unsuppported-videoplayer").insertAfter($(".brightcoveplayer, .cmp-p-videoplayer"));}

Watch and learn more:

Features & Benefits of the Eutech 1730 Dissolved Oxygen Bench Meter

Premium

Advanced

Basic

Eutech DO 450 Portable Dissolved Oxygen Meter
Eutech DO 600 Portable Dissolved Oxygen Meter
Eutech DO 6+ Portable Dissolved Oxygen Meter
Compatible probesRDOPolorographicPolorographic
DO range (polarographic)---0 to 90.00 mg/L or ppm0.00 to 19.99 mg/L or ppm
DO range (RDO optical)0 to 200 %; 0 to 20 ppm/mg/L------
DO calibration modesZero and saturation2-point (0 %, 100 %),
1-point (mg/L)
2-point (0 %, 100 %),
1-point (mg/L)
Barometric pressure compensationManual450 to 825 mmHg /
59.9 to 109.9 kPa
500 to 1499 mmHg /
66.6 to 199.9 kPa (Manual Input)
Salinity correctionManual0.0 to 50.0 ppt (Manual Input)0.0 to 50.0 ppt (Manual Input)
Backlit displayYesYes---
Number of channels111
Data log500 with time and date stamp500 with time and date stamp---
Data export optionsUSB or RS232IrDA, RS232C (via LED)---
AC adapter9 V DC adapter, 1.3 A
(100/240 VAC, SMPS) (optional)
9 V DC adapter---
Battery powerTwo AA batteries (included)Included—4AAs4 x AAA batteries

Orion Bench Meters

Premium

Advanced

Basic

Orion Versa Star Pro RDO/DO
(VSTAR30series)
Orion Star A213 RDO/DO
(STARA2130 series)
Orion Lab Star DO113 DO
(Lab Star series)

Versatile, high-performance laboratory measurement systemEasy-to-use, dependable laboratory metersEconomical, simplified
laboratory meters
Ideal for
applications in:
Pharmaceuticals, biotechnology, food and beverage, industrialWater,
wastewater,
chemical, contract testing
Academic,
environmental,
power
Compatible probesOptical, polarographicOptical, polarographicPolarographic
DO range (polarographic)0 to 90 mg/L, 0 to 600%0 to 90 mg/L, 0 to 600%0 to 30 mg/L, 0 to 300%
DO range (RDO optical)0 to 50 mg/L, 0 to 500%0 to 50 mg/L, 0 to 500%---
DO calibration modesWater-saturated air, air-saturated water, manual (Winkler), zero pointWater-saturated air, air-saturated water, manual (Winkler), zero point100% and 0% saturation; custom concentration value
Barometric pressure compensationAutomatic with built-in barometerAutomatic with built-in barometerAutomatic with manual value input
Salinity correctionAutomatic with conductivity module and probe or manual inputAutomatic with manual factor inputAutomatic with manual factor input
Backlit displayYesYesYes
Number of channels4, customizable with modules11
Stirrer probe inputs21---
Data log2,000 with date/time2,000 with date/time500 sets with date/time
Calibration log30 per mode101
Identification optionsElectrode ID, sample ID, user IDSample ID, user ID---
Data export outputComputer or printerComputer or printerComputer or printer
Power supplyUniversal, 1000150–240 VAC, 50–60 Hz (Cat. No. STARA-PWR)Universal, 100–240 VAC, 50–60 Hz (Cat. No. 1010003) or 4 AA batteriesUniversal, 100–240 VAC, 50–60 Hz (Cat. No. LSTAR-PWR), 9DC adapter, 1.3A
Enhance your productivity with accessories for your benchtop and portable meters.Meter Accessories ›

Orion Portable Meters

Premium

Advanced

Basic

Orion Star A323 Dissolved Oxygen
(STARA3230 series)
Orion Star A223 Dissolved Oxygen
(STARA2230 series)
Orion Star A123 Dissolved Oxygen
(STARA1230 series)
Compatible probesRDO, polarographicRDO, polarographicPolarographic
DO range (polarographic)0 to 600% saturation0 to 600% saturation0 to 200% Saturation
DO range (RDO optical)0 to 50 mg/L0 to 50 mg/L---
DO calibration modesWater-saturated air, air saturated water, manual (Winkler), and zero pointWater-saturated air, air saturated water, manual (Winkler), and zero pointWater-saturated air, manual (Winkler)
Barometric pressure compensation400 to 850 mmHg,
automatic or manual
400 to 850 mmHg,
automatic or manual
---
Salinity Correction0 to 45 ppt0 to 45 ppt0 to 45
Backlit DisplayYesYes---
Number of channels111
Data log5000 with time and date stamp1000 with time and date stamp50
Data export optionsRS232,USBRS232, USBRS232, USB
AC AdapterOptional—universal,
100-240 VAC
Optional—universal,
100-240 VAC
Optional—universal,
100-240 VAC
Battery powerIncluded—4AA'sIncluded—4AA'sIncluded—4AA's
Enhance your productivity with accessories for your benchtop and portable meters.Meter Accessories ›

Eutech Bench Meters

Advanced

Basic

Eutech DO2700 Dissolved Oxygen Bench MeterEutech 1730 Dissolved Oxygen Bench Meter

Economical, routine laboratory metersBudget-friendly, simple laboratory meters
Compatible probesPolarographicGalvanic
DO range (Polarographic)0.00 to 50.00 mg/L; 0 to 600.0 % saturation---
DO range (Galvanic)---0 to 30 mg/L; 0 to 300.0 % saturation
DO calibration modesWater-saturated air, zero point, manual (Winkler)100% and 0% saturation, manual concentration value (Winkler)
Barometric pressure compensationAutomatic with built-in barometerAutomatic with manual value entry
Salinity correctionAutomatic with manual value entryAutomatic with manual value entry
Range (temperature)0.0 to 50.0 °C, 32.0 to 122.0 °F-5.0 to 105.0 ºC
Backlit displayYesYes
Number of channels11
Stirrer probe inputsYes---
Data log500 with date/time500 with date/time
Calibration logMost recent viewable on meter and stored in meter memoryActive dissolved oxygen, temperature with time and date
Data export optionsRS232Computer or printe
Power supplyUniversal, 100-240VAC, 50/60 Hz, Cat. No. 60X426401Universal, 100–240VAC, 50–60Hz (Cat. No. EB1700PWR), 9 DC adapter, 1.3A

").addClass("unsuppported-videoplayer").insertAfter($(".brightcoveplayer, .cmp-p-videoplayer"));}

Watch and learn more:

Features & Benefits of the Eutech 1730 Dissolved Oxygen Bench Meter

Eutech Portable Meters

Premium

Advanced

Basic

Eutech DO 450 Portable Dissolved Oxygen Meter
Eutech DO 600 Portable Dissolved Oxygen Meter
Eutech DO 6+ Portable Dissolved Oxygen Meter
Compatible probesRDOPolorographicPolorographic
DO range (polarographic)---0 to 90.00 mg/L or ppm0.00 to 19.99 mg/L or ppm
DO range (RDO optical)0 to 200 %; 0 to 20 ppm/mg/L------
DO calibration modesZero and saturation2-point (0 %, 100 %),
1-point (mg/L)
2-point (0 %, 100 %),
1-point (mg/L)
Barometric pressure compensationManual450 to 825 mmHg /
59.9 to 109.9 kPa
500 to 1499 mmHg /
66.6 to 199.9 kPa (Manual Input)
Salinity correctionManual0.0 to 50.0 ppt (Manual Input)0.0 to 50.0 ppt (Manual Input)
Backlit displayYesYes---
Number of channels111
Data log500 with time and date stamp500 with time and date stamp---
Data export optionsUSB or RS232IrDA, RS232C (via LED)---
AC adapter9 V DC adapter, 1.3 A
(100/240 VAC, SMPS) (optional)
9 V DC adapter---
Battery powerTwo AA batteries (included)Included—4AAs4 x AAA batteries
Dissolved Oxygen (DO) Meters - UK (2024)

References

Top Articles
Latest Posts
Article information

Author: Patricia Veum II

Last Updated:

Views: 5967

Rating: 4.3 / 5 (44 voted)

Reviews: 83% of readers found this page helpful

Author information

Name: Patricia Veum II

Birthday: 1994-12-16

Address: 2064 Little Summit, Goldieton, MS 97651-0862

Phone: +6873952696715

Job: Principal Officer

Hobby: Rafting, Cabaret, Candle making, Jigsaw puzzles, Inline skating, Magic, Graffiti

Introduction: My name is Patricia Veum II, I am a vast, combative, smiling, famous, inexpensive, zealous, sparkling person who loves writing and wants to share my knowledge and understanding with you.